Schematic 3D Integrator
User Guide
Integrator Functions in Detail
:
How Integrator Compares Schematic and 3D Data
: Compare Colour Codes
Compare Colour Codes
Integrator colour codes the diagram and 3D views to give a visual indication of the compare results. Each view is coloured with respect to the other. Colours are configurable but there is a typical setup:
•
Objects that match correctly are shown in green.
•
If an object exists on the diagram but is missing in 3D, it will be shown in red on the diagram, and vice versa.
•
In the case of a piping component missing, the line segment it is missing from will be shown in yellow.
•
A yellow line segment on the diagram indicates a missing tube in 3D.
•
In the case of a missing nozzle, the equipment body is coloured yellow.
•
Connection errors will be shown in blue.
•
Attribute mismatches will be shown in orange.
•
An ambiguous object, e.g. a valve matched in two places, will be shown in red.
•
An object with the wrong owner, e.g. a nozzle on the wrong equipment, will be shown in orange.
•
Objects not compared are shown in cyan.
1974 to current year.
AVEVA Solutions Limited and its subsidiaries. All rights reserved.