ISODRAFT
User Guide
Symbol Keys
:
Universal SKEYs
: Connection Labelling
Connection Labelling
When fittings are very complicated, the offlegs on the isometric plot cannot always be related easily to the true geometry of the detailed fitting. To aid the fabricator, the relevant p-point number is output at each connection point on the isometric. This number is prefixed with ATEXT 388 (default setting ‘P') and is drawn inside an ellipse to distinguish it from other messages. When the user uses a universal SKEY, the user is responsible for making sure that the detail plot has connection p-points marked in this way. If ATEXT 388 is set to blank, no messages will be output
1974 to current year.
AVEVA Solutions Limited and its subsidiaries. All rights reserved.