ISODRAFT
Reference Manual
Command Reference Section
:
Alphabetical Command Reference
: INSULATIONCONTROL
INSULATIONCONTROL
Function:
Specifies whether or not insulation is to be plotted.
Description:
Any piping component which has its ISPEC attribute set may be shown insulated. The start and end points of insulated components will be shown on the isometric.
Insulation and tracing can be shown:
•
On tubing only
•
On tubing and pipe components
The name of the insulation and/or tracing specification will be shown in the title block.
Examples:
INSU ON
Display insulation.
INSU TUBE
Show insulation on the tube only, not on the pipe components.
INSU ALL
Show insulation on both tube and components.
INSU OFF
Suppress the display of insulation.
The default is INSULATIONCONTROL TUBE.
Related Commands
:
TRACINGCONTROL
Command Syntax
:
>------
INSUlationcontrol
----+----
ON*
----.
|
|
|----
TUBE
---|
|
|
|----
ALL
----|
|
|
‘----
OFF
----+--->
Querying:
Q INSUlationcontrol
Q OPTions
1974 to current year.