DRAW Reference Manual
Intelligent Text
:
Distance, Position and Bore Data Output
: Mixed Units within Intelligent Text Strings
Mixed Units within Intelligent Text Strings
The units used in intelligent text strings are determined by the UCOD attribute of the owning LAYE or appropriate Style. However, it is possible to insert a ‘switch units’ code in the text string, which causes all distances and bores that follow to be output in ‘alternate’ units.
Primary Units
Default Alternate Units
INCH DECI
MM
INCH AVEVA
MM
INCH US
MM
FINCH AVEVA
MM
FINCH US
MM
FT
METRE
MM
INCH DECI
CM
INCH DECI
METRE
INCH DECI
The ‘switch units’ code is
%U
so, for example, to generate a dimension in both Imperial and metric units, with the second value in brackets, the intelligent text string:
’#DIM() %U(#DIM())’
can be used. The units can be switched back to the standard units by a subsequent use of a %U code.