Model Reference Manual
Data Consistency Checking
:
Setting Geometric Error Limits
: Structural Joints
Structural Joints
The positional errors for Joints are measured as divergences of the Joint positions from their owning Nodes. The maximum permissible errors are defined, as for Sections, in terms of a Joint’s
eccentricity
.
Note:
Joint eccentricities are defined
separately
for Pjoint (Primary Joint) and Sjoint (Secondary Joint) elements.
Keywords:
ECCENTRICITY PJOINT SJOINT
Description:
The ECCENTRICITY PJOINT and ECCENTRICITY SJOINT commands specify the maximum permissible distance between the position of a Primary Joint or a Secondary Joint, respectively, and that of its owning Node before a diagnostic message is output.
Examples:
ECC PJOINT 1
(Default)
Maximum error in Primary Joint position is 1 mm
ECC SJOINT 1
(Default)
Maximum error in Secondary Joint position is 1 mm
ECC PJOIN 0.1 INCH
Maximum error in Primary Joint position is 0.1 inch
ECC PJOIN DEFAULT
Resets permissible Primary Joint error to 1 mm
ECC SJOIN DEF
Resets permissible Secondary Joint error to 1 mm
Command Syntax:
>--- ECCentricity ---+--- PJOInt --.
| |
‘--- SJOInt --+--- <uval> ----.
| |
‘--- DEFault -----+--->
Querying:
Q ECCentricity ---+--- PJOInt --.
| |
‘--- SJOInt ---+--->
1974 to current year.