Model Reference Manual
Piping, Ducting and Cable Trays
:
Re-selection of Existing Components and Tube
: General Reselection of Components and Tube
General Reselection of Components and Tube
Keywords:
RESELECT
Description:
This command allows existing Components and Tube to be Reselected according to new parameters. Where new parameters are not stated or available through defaults, they are obtained from the old Component Specification entries.
Examples:
RESEL WITH STYPE BALL
The current element and Leave Tube will be Selected using any default parameters and the STYPE specified. Any further parameters required will be obtained from the old Specification Component.
RESEL WI SPEC /NEWSPEC
The current element and Leave Tube will be Selected using the new Specification and any default parameters. The remaining necessary parameters will be obtained from the old Specification Component.
RESEL TUBE WI STYPE GLAS (At Branch)
The current element HSTU attribute will be Selected using default parameters and the specified STYPE. If any further parameters are necessary they will be obtained from the old Specification Component.
Command Syntax:
>-- RESElect --+-- SPref ---.
| |
|-- LStube --|
| |
|-- HStube --|
| |
|-- LSrod ---|
| |
|-- HSrod ---|
| |
|-- TUbe ----| .-------<------.
| | / |
‘-- ROD -----+-- WIth -- *-- SPec <gid> --|
| |
|-- <wivl> ------|
| |
|-- <wiwor> -----’
|
‘-->
Querying:
.-----<-----.
/ |
>-- Q SPECification --*-- <qspci> --+-->
<qspci> is explained in
Standard Syntax Graphs
.
>-- Query --+-- SPRef ---.
| |
‘-- TUbe ----+-->
1974 to current year.
AVEVA Solutions Limited and its subsidiaries. All rights reserved.