Model Reference Manual
Piping, Ducting and Cable Trays
: Re-selection of Existing Components and Tube
Re-selection of Existing Components and Tube
If a Component or Tube is required to be respecified, the user may restate any of the Selection commands described elsewhere in this manual. However, each time this is done all the
non-default
Specification entries must be restated, even if most or all of these are identical to the old Specification Component.
The RESELECT command allows the designer to make use of the original Selection parameters for a Component to simplify the Selection of a new Component. This is useful for situations where only a single change has taken place since the original Selection; for example, if the Branch Specification (PSPE attribute) was changed or the nominal bore of a group of Components had to be increased.
The RESELECT command operates as follows:
1.
Any new Selection parameters are considered (either changed defaults or specified by the user).
2.
If any more parameters are required, they are obtained from the old Specification Component.