Data Model
Reference Manual
Pseudo Attributes
: Attribute Category: Hull
Attribute Category: Hull
Attribute Name
Data Type
Qualifier
Description
APARMS
real(9)
All parameters
ASREF
element
Assembly reference
ASSNST
element
Assembly Nest
ATWLEN
real
Assembly total weld length
BEALAM
string(12)
Name of the bead laminate code
BEAPOS
integer
Bead posno
BEAQUA
string(26)
Bead quality
BEAWTH
real
Bead width
BENT
logical
Bent flag
BEVEL
real
Bevel
BEVFLA
real
Bevel code, flange
BEVLFT
real
Bevel code on left side of seam
BEVM
real(2)
Bevel codes along M1 and M2 curves
BEVRGT
real
Bevel code on right side of seam
BEVTXT
string
Bevel text
BEVWEB
real
Bevel code, web
BLCKLM
logical
True if block limit seam
BURNID
string(80)
Burner id
BUYMRK
string(26)
Buying mark
CAXISE
string
Coordinate axis enumerated
CHALEN
real
Length of chamfer intervals
CHANUM
integer
Number of chamfer intervals
CLIPCD
integer
Clip code
CLMPLN
real
Clamping length of manufactured profile
CLNELS
element(100)
References to panels or components in the same clone chain
CLOSED
logical
True if plate covering entire referenced component
CMALL
real
Structure allowance
CMBOUA
element
Aft boundary
CMBOUF
element
Fwd boundary
CMBOUL
element
Lower boundary
CMBOUP
element
Ps boundary
CMBOUS
element
Stbd boundary
CMBOUU
element
Upper boundary
CMBOX
real(6)
Bounding box
CMCAT
string(256)
Compartment category
CMCDE
real
Content density
CMCTID
string(256)
Content type ID
CMDESC
string(256)
Compartment description
CMFLW
real
Full Load Weight
CMLCV
real
Longitudinal centre of total volume
CMMGE
integer
Merged compartment indicator
CMPER
real
Compartment permeability
CMPERD
real
Permeability for use in damage
CMPURP
string(256)
Purpose
CMTCV
real
Transverse centre of total volume
CMTYP
integer
Type of compartment
CMVCV
real
Vertical centre of total volume
CMVOL
real
Total volume
CNTNUM
integer
Contour number
COMNT
string
Comment
CONAM
string
Cutout name
CONCD
integer
Connection code
CONDES
string
Connection string
CONTYP
string
Connection type
CORNUM
integer
Corner number
DATINT
integer(2)
Date
DEST
string(26)
Destination
DIST
real(2)
Distances
DISTM
real(2)
Distances to M1 and M2 curves
DSGNTN
string
Designation
DSTNCE
real
Distance
DTWTCL
string
Date of weight/cog calculation
EDPUV
pos
End point
EPARAM
real(6)
Evaluated parameters
EXCESS
real
Excess
EXCLEN
real(3)
Length of excess intervals
EXCLFT
real
Excess on left side of seam
EXCNUM
integer(3)
Number of excess intervals
EXCRGT
real
Excess on right side of seam
EXCTLF
integer
Excess type on left side of seam
EXCTRG
integer
Excess type on right side of seam
EXTBOX
real(6)
Extended block box
EXTNSN
real
Extension
FLATYP
integer
Flange type
FNCCD
integer
Functional description code
FNCTXT
string(80)
Functional description
FOLDED
logical
True if folded
FULLEN
real
Total length of manufactured profile
GENSTR
string
integer
General strings
GPSTR
string(26)
integer
General purpose strings
GRILEN
real
Length of grinding intervals
GRIND
real
Grinding info
GRINUM
integer
Number of grinding intervals
HASCLN
logical
Has clones flag
HGHT
real
Height
HLCOLO
string
Hull Colour
HULCNT
integer
Size of hull array/collection
HULLOB
element
Hull object reference
HULOC
string
Location
HUMVW
string
Model View
HUREFL
logical
Reflected
HUREPL
element
Replica
HUSYMM
logical
Symmetrical
HYWTSU
real
Wetted surface
IDENT
string
Panel identification string
INCL
real
Inclination angle
INSTNC
string
Bracket instance name
ISECPT
pos
word, integer
Intersection point
KNUANG
real
Knuckle angle
KNUCKL
logical
True if knuckled
LAMDIS
logical
True if Lam Displ
LAMINA
string(12)
Name of first laminate code
LAMINB
string(12)
Name of second laminate code
LAMWTH
real
Width of laminate
LIMNUM
integer
Order number of limit
MACRID
string
Clip macro ID
MANBLK
string
Name of owner block
MANLEN
real
Length of manual intervals
MANNUM
integer
Number of manual intervals
MANPAN
string
Name of owner panel
MANTRA
real(16)
Transformation from local coordinate system
MIBSHP
word
Burning shape
MIRROR
logical
True if mirrored in local v-axis
MICOMP
word
Movement instruction valid for
MIPSID
word
Profile end
MISIDE
word
Movement instruction side
MNDIRE
string(9)
Main direction enumerated
MNSIDE
string(9)
Main side enumerated
MODREF
element(100)
Model references
MOULEN
real
Mould length
NOMARK
logical
True if unmarked
NOPGS
integer
Number of openings
NPRVEC
real(2)
Local rotation vector of part
NPXYP
real(2)
Position of part(x,y)
NTRLEN
real
Neutral length
OBJCD
integer(2)
Object codes
OFFSET
real
Offset
OGDSTS
real(25)
Distances to openings
OTHLEN
real
Length of other intervals
OTHNUM
integer
Number of other intervals
OUAREA
real
Outer area
OUTFRF
element
Reference of matching outfit object
OVRSH
real
Overshoot (d-measure) for unsymmetrical flange
PANOTL
element(100)
References to limiting panels
PANREF
element
Panel reference
PANSID
integer
Side of panel
PARAL
logical
True if tap parallel to referred seam
PARM
real(6)
Parameters
PARNAM
string(256)
Part name
PARREF
element(10)
Part reference
PDELE
element
Reference of matching hull object
PECPAR
string
word
Endcut parameters
PLAREA
real
Area
PNTUV
pos
Point2D
PNTXYZ
pos
Point3D
POINUM
integer
Point Num
POSNO
integer
Position number
PRTIDL
string(132)
Long part id
PRTIDM
string(132)
word
Module part id
PRTIDS
string(132)
Short part id
PRTLST
string(26)
Parts list name
QUACD
integer
Quality code
QUATXT
string(26)
Quality
RAWPLA
element
Raw Plate
REFLCL
logical
True if reflected in CL
RSBOX
real(6)
Bounding box of RSO
RSFFD
integer
Functional description on face
RSFMC
integer
Material code on face
RSFMS
string(256)
Material side on face
RSFMT
real
Material thickness on face
RSFSA
logical
Auto stiffening on face
RSFSD
string(256)
Profile dim on face
RSFSS
string(256)
Stiffener side on face
RSFST
integer
Profile type on face
RSFWT
logical
Watertight
RSLBRA
string(256)
Bracket instance at limit
RSLELE
element
Limiting element
RSLPRE
integer
Profile end definition at limit
RSPAN
element(1000)
Panel(s) defined on RSO
RSPLN
integer
Principal plane of RSO
RSTYP
integer
Type of RSO
SCHEME
string
Scheme name
SDTINT
integer(2)
Splitting date
SDTTXT
string(22)
Splitting date
SHFALG
real
Shrinkage factor along main direction
SHFPRP
real
Shrinkage factor perpendicular to main direction
SHFSEA
real
Shrinkage factor for seams perp. to main direction
SHPUV
pos
Point defining shrinkage
SHVUV
dir
Vector defining shrinkage
SPECIF
logical
True if outer panel contour on PS/SB are different
SPLA
string
Name of spigot plate
SPPOSN
integer
Position number of spigot plate
STPUV
pos
Start point
STREAT
string(26)
Surface treatment
STRXPL
logical
True if surface treatment explicitly defined
SYMELE
element
Symmetric element
SYMLNS
integer
Side of direction vector
SYMM
integer
Symmetry code
SYMXYZ
dir
Vector along symmetry line
TAGCD
integer
Tag code
TAGCDS
integer(25)
Tag codes
TAGNMS
integer(25)
Tag numbers
TAGNUM
integer
Tag number
TGHETP
string(20)
Type of Tightness code
TOTLEN
real
Total manual length
TPLFRR
element(10000)
integer
Topology references - from
TPLFRT
integer(10000)
element
Topology reference types - from
TPLTOR
element(10000)
integer
Topology references - to
TPLTOT
integer(10000)
element
Topology reference types - to
TVALS
real(1000)
t Values
TWIST
logical
True if twisted
TWSTAN
real
Twist angle
TYPECD
integer
Type code
TYPECE
integer
Type code
VBEVEL
logical
True if V-bevel
WELDDP
real
Welding depth
XBEVEL
logical
True if X-bevel
YBEVEL
logical
True if Y-bevel
1974 to current year.
AVEVA Solutions Limited and its subsidiaries. All rights reserved.