Pipe Spool Drawing Administration : Position and Populate Spool Drawing Backing Sheet : Backing Sheet MTO Table Entries Note
Note:
In order for the note to be identified as a spool drawing MTO table entry, the SpPurp attribute must be set to CELLS and the Function attribute set to MTO.
The MTO table entry note shxyposition attributes must be populated to define the top left corner of the MTO table. The values are measured from the bottom left of the backing sheet.
The text fields on the backing sheet can be added using the Pipe Spool Drawing Admin window. Refer to Pipe Spool Drawing Administration for further information.
The final step is to deselect the Lvisibility attribute check box for the table entry note element, the elements become hidden from view.