Catalogues and Specifications
User Guide
Supports
:
Modify User Defined Ancillary Geometry
: Geometry Sets
Geometry Sets
The geometry sets are created in project MDU. The examples display what is added and details any properties that are used. You can add geometry using the properties if required and add additional properties as necessary.
AT500 to AT700, BT500 to BT700, LT500 to LT700
Simple Box Representation
The box is set to a length of 10, and uses the pipe outside diameter (OD) as the X and Y length.
The three standard catalogue parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1. All other design parameters are set to 0 (zero), as indicated in the
Properties
window.
No user editable design parameters have been defined.
AN500 to AN569
Anchor for Shoes
Simple Anchor Representation
These user standards ask for a pipe shoe to be identified so it can read the shoe parameters Shoe Height and Flange Width in order to size the anchor. It then asks for a section or box to be identified to read the anchor width across the section of box.
The three standard catalogue parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1, 100, 102 and 133.2. All other design parameters are set to 0 (zero), as indicated in the
Properties
window.
Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added.
AN570 to AN639
Anchor for Pipes
Simple Box Representation
The three standard catalogue parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1. All other design parameters are set to 0 (zero), as indicated in the
Properties
window.
No user editable design parameters have been defined.
GT500 to GT569
Guide for Shoes
Simple Guide Representation
These user standards ask for a pipe shoe to be identified so it can read the shoe parameters Shoe Height and Flange Width in order to size the guide.
The three standard catalogue parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1, 100 and 102. All other design parameters are set to 0 (zero), as indicated in the
Properties
window.
Design parameters 1, 2, 3 and 4 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added.
GT570 to GT639
Guide for Pipes
Simple Guide Representation
The three standard catalogue parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1 and 0. All other design parameters are set to 0 (zero), as indicated in the
Properties
window.
ST500 to ST569
Stop for Shoes
Simple Stop Representation
These user standards ask for a pipe shoe to be identified so it can read the shoe parameters Shoe Height and Flange Width in order to size the Anchor. It then asks for a section or box to be identified to read the anchor width across the section of box.
The three standard catalogue parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1, 100 102 and 133.2. All other design parameters are set to 0 (zero), as indicated in
Properties
window.
Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added.
ST570 to ST639
Stop for Pipes
Simple Box Representation
The three standard catalogue parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1. All other design parameters are set to 0 (zero) as indicated in the
Properties
window.
AN640 to AN700
Anchor for Trunnions
Simple Anchor Representation
The three standard catalogue parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset. The Plate Length, Plate Width and Plate Thickness are obtained from the identified Base Plate. All other design parameters are set to 0 (zero) as indicated in the
Properties
window.
Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added.
ST640 to ST700
Stop for Trunnions
Simple Stop Representation
The three standard catalogue parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset. The Plate Length, Plate Width and Plate Thickness are obtained from the identified base plate. All other design parameters are set to 0 (zero) as indicated in the
Properties
window.
Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added.
GT640 to GT700
Guide for Trunnions
Simple Guide Representation
The three standard catalogue parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset. The Plate Length, Plate Width and Plate Thickness are obtained from the identified base plate. All other design parameters are set to 0 (zero) as indicated in the
Properties
window.
Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added.
AC500 to AC599
Ancillary Component for Trunnions
Simple Ancillary Representation
The three standard catalogue parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1. All other design parameters are set to 0 (zero), as indicated in the
Properties
window.
No user editable design parameters have been defined.
AC600 to AC700
Plate Component for Trunnions
Simple Plate Representation
The three standard catalogue parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1. All other design parameters are set to 0 (zero), as indicated in the
Properties
window.
No user editable design parameters have been defined.
CA500 to CA700
Cable Tray Ancillaries
Simple Cable Tray Ancillary Representation
The three standard catalogue parameters have been added, Nominal Bore, Outside Diameter and Connection type and 21 design parameters have been created. The design parameters are set to 0 (zero) as indicated in the
Properties
window. Cable ancillaries do not include Minimum/Maximum Insulation and Minimum/Maximum Temperature parameters. The Outside Diameter is always set to 0 (zero) for cable tray ancillaries.