Catalogues and Specifications
Reference Manual
Piping Components
: Example Connection Type Codes
Example Connection Type Codes
Naming of the P-point PCON attribute of a Piping Component requires early consideration. The PCON name is for use mainly in data consistency checking, but also by ISODRAFT for working out bolting details. The rules for ISODRAFT are as follows:
•
The first letter of the PCON attribute of a flange must be ‘F’ or ‘L’ (the latter for lap joints)
•
The first letter of the PCON attribute of a gasket must be ‘G’
•
The first letter of the PCON attribute of a wafer fitting must be ‘W’
The list below is not exhaustive and only shows example codes - it is not mandatory.
Item and/or Connection Type
Code
300lb Raised-Face Flange
FGD
300lb Gasket
GGD
Pipe Bevelled End
TUB
Butt Weld
BWD
Socket Weld
SWF
300lb Wafer Fitting
WGD
Screwed Male
SCM
Screwed Female
SCF