Diagrams
User Guide
Diagrams
:
Piping & Instrumentation Diagrams (P&IDs)
:
Instrumentation
:
Elements
: Actuator Element (SCACTU)
Actuator Element (SCACTU)
SCACTU is representing a Schematic Actuator in the schematic database. Its attribute set and behaviour is very much like SCOINS and its primary owner is the same as for the SCOINS element. The differences between SCACTU and SCOINS are in:
•
the item they represent
•
the element they can refer to
•
the way the user can manipulate them in the AVEVA Diagrams application.
SCACTU is able to refer (attach) to another inline component, such as SCVALV, SCFITT and SCINST. The SCOINS shape accomplishes this by using the Control Handle. On the contrary, the SCACTU has a an outwards connection point used to build up the reference in the diagram (SCNOZZ works similarly).
Actuators can be connected to:
•
equipments
•
sub-equipments
•
offline instruments
•
other actuators
•
valves
•
fittings
•
inline instruments
•
HVAC fittings
It is possible to connect control lines for actuator behaviour managing.