Note:
|
All HVAC Components later created below the branch will use the Specification selected in this drop-down list. To use different specifications within a ductwork run, a new branch must be created at each point a different specification is used.
|
•
|
East0 North0 Up0 - (default) positions the branch head at the co-ordinates 0,0,0 (origin).
|
•
|
Head of ID Branch - Position the Branch Head at the Head of an existing Branch. The user will be prompted to click in the 3D View at the position of the existing Branch Head.
|
•
|
Tail of ID Branch - Position the Branch Head at the Tail of an existing Branch. The user will be prompted to click in the 3D View at the position of the existing Branch Tail.
|
•
|
ID Nozzle - Position the Branch Head at the end of an existing Nozzle element. The user will be prompted to click in the 3D View at the position of the existing Nozzle.
|
•
|
ID Ceiling Fitting - Position the Branch Head at the end of an existing Ceiling element. The user is prompted in the 3D View to Identify HVACFI.
|
•
|
Cursor - The user will be prompted to click anywhere in the 3D View. Where the user clicks will be used as the position for the new Branch Head.
|
•
|
ID Design Point - Position the Branch Head at the position of a P-point of an existing element. The user will be prompted to click in the 3D View on the P-point of an element.
|
•
|
Explicit - Display the Head Position window, which allows the user to enter values in the text fields or click Pick Position to make a graphical pick.
|
•
|