General and Database Commands
:
Miscellaneous Facilities
: Switching Text Output Off (DEVICE TTY only)
Switching Text Output Off (DEVICE TTY only)
The TRACE command is only relevant in TTY mode. It controls the automatic output of the Current Element name. With TRACE set to ON, the name of an element is displayed as it is accessed. With Trace set to OFF, the element name is not displayed. When macros are being run, TRACE is always set to OFF automatically.
Example:
TRACE OFF
stops the automatic name output.
TRACE ON
(default) restarts automatic output of Current Element name.