Database Management
Reference Manual
Attributes
: Real Attributes of Physical Quantities
Real Attributes of Physical Quantities
Real attributes can be purely numeric, but often they may be representing physical quantities. The type of a physical quantity is its (physical) dimension.
Attributes of physical quantities are consistently stored in the database in defined database units, irrespective of the current working units, or of the units of any value entered by the user. The whole system operates on the expectation that all stored values of physically dimensioned quantities are in their relevant standard database units.
The following table lists the dimensions understood by the system giving:
Their name (or description) recognised by the system,
The assigned hashcode,
The database storage units.
Supported standard units for the quantity
For example attributes of length have a hash code of DIST are stored in mm and other standard units include inch, cm, ft, metre etc.
Name of Dimension
HashCode/Word
Database Units
Other Specific Units
Comments
AbsPressure
ABSP
pascal
bar atm PSI torr mmHg inHg
pressure may be absolute or gauge
Angle
ANGL
degree
radian grade arcmin arcsec
AngularMomentum
ANGM
N.m.s
Area
SQDI
mm2
acre hectare
Bore
BORE
mm
in
Range of bore units limited to mm and inch (and Finch)
Capacitance
CAPA
farad
Charge
CHAR
coulomb
Conductance
COND
siemens
Content
PCUD
mm-3
Currency
CURY
USDollar
UKPound Euro
Current
CURR
ampere
Density
DENS
kg/m3
DensityMANDB
MAND
kg/mm3
densities stored in MANU database
ElectricConductivity
CNDT
Si/m
ElectricField
EFLD
V/m2
EMF
EMF
volt
Energy
ENER
kiloWatthour
joule BTU cal
EnergyDensity
EDEN
kg/m3
Force
FORC
newton
poundal dyne kgF lbF
FoulingFactor
FFAC
m2.K/W
Frequency
FREQ
hertz
rpm
GaugePressure
GAGE
pascal
bar atm PSI torr mmHg inHg
pressure may be absolute or gauge
HeatCapacity
ENTR
J/m
HeatingValue
HVAL
J/m3
HeatTransferCoeff
HTRA
W/m2/K
Impedance
IMPE
ohm
Inductance
INDU
henry
Inertia
INER
kg/m2
KinematicViscosity
KVIS
m2/s
Length
DIST
millimetre
m in ft cm km mile yard micron thou angstrom
LinearDensity
PDIS
mm-1
MagFieldIntensity
MFIN
A/m
MagFluxDensity
MFXD
tesla
MagneticFlux
MGFX
weber
Mass
MASS
kilogram
gram tonne pound oz longTon shortTon cwt
MassFlow
MFLO
kg/s
Momentum
MOME
N.s
Permeability
PMBT
H/m
Permittivity
PMTT
F/m
Power
POWE
kiloWatt
hp watt
Pressure
PRES
pascal
RadiationDose
RDOS
sievert
radd rem gray
Radioactivity
RADY
bequerel
curie
Resistivity
REST
ohm/m
RotationalStiffness
STFR
N.m/rad
SpecHeatCapacity
SHCP
N/K
SpecificEnergy
SENG
J/kg
Speed
SPEE
m/s
Stiffness
STIF
N/m
SurfaceDensity
PSQD
mm-2
Temperature
TEMP
degCelsius
degF K degRankine
TemperatureGradient
TPDI
degC/mm
ThermalConductivity
TCON
W/m/K
ThermalResistance
TRES
K/W
Time
TIME
second
min hr day month week year
Torque
TORQ
N.m
UnitMass
UMAS
kg/mm
ViscosityDynamic
VISC
s/Pa
Volume
CUDI
mm3
litre ImpGallon USGallon
VolumetricFlow
VFLO
m3/s
None
NONE
numerical real attribute
WORD
WORD
used in assigning parameter dimensions etc.
Parameter
UNIPAR
used for parameter attributes
1974 to current year.
AVEVA Solutions Limited and its subsidiaries. All rights reserved.