Select Utilities > Surface Treatment > Define from the main menu to display the
Surface Treatment Definition window.
The Paint Definition sub window is used to define a list of allowable paints. Each entry in the List of PAINT Elements may be referenced by one or more entries in the surface treatment specification.
The Create,
Copy and
Refresh options perform similar functions to the Surface Treatment options.
Specify the coating Thickness (this is the Dry Film Thickness in microns) and click
UPDATE. The value will be copied to the
THICKNESS (MICRONS) field in the Selected Coatings list.
The Move Coating arrow icons are used to change the order in which the coatings appear in the Selected Coatings list (i.e. the order in which the coatings are to be applied). The Move Coating operations are also available from the right-click options menu. There are also options for removing a selected coating or all coatings.