Data Integrity Checking
:
DICE Output
: Error Report
Error Report
During the checking of the structure of each DB, DICE will output a diagnosis of each error as it is found. These messages, which are output as part of the normal operation, are quite distinct from any general error messages which may result from the incorrect running of DICE as an AVEVA E3Dâ„¢ module.
If a BRIEF mode is required, DICE will diagnose any number of warnings up to the first error found and will then abandon any further checking. BRIEF mode is selected by setting the Maximum number of errors on the
Database Integrity Check
form to 1.
If a FULL mode is required, DICE will output a list of all errors found, unless the number of errors exceeds the setting of Maximum number of errors or the number of warnings exceeds the setting of Maximum number of warnings.