Pipe Stress Interface - R2
User Guide
Introduction
: Settings and Definitions
Settings and Definitions
AVEVA E3D™ communicates with Rohr2 using ASCII files. These files are stored in a directory that is declared by the environment variable %R2STRESS%. In addition, a project specific environment variable, %xyzR2STRESS%, can be used (xyz is the project code).
If both environment variables are set and both directories exist, the project specific directory is used.
It is recommended to use the project specific environment variable because of project related settings and different displacement files for each project.
The following file extensions are used by the interface to transfer data:
Extension
Description
Direction
.ntr
File with geometry data.
AVEVA E3D™ to Rohr2.
.ntrerror
Log file for transfer of geometry.
.r2hangprop
File with data for hanger points.
Rohr2 to AVEVA E3D™.
.r2hangerror
Log file for hanger points.
.r2disp
File for displacement data.
AVEVA E3D™ Hanger Type Description
An overview of the allowed Hanger Types is available, refer to
Hanger Types
for further information.
1974 to current year.
AVEVA Solutions Limited and its subsidiaries. All rights reserved.