The Piping Bend Radius Defaults limits the bend radiuses available for selection from the
Bend Information part of the
Component Editor window, when using variable radius bends.
Use to set the default range of multipliers available for selection from the Bend Information part of the
Component Editor window. The actual bend radius is set to the multiplier * the outside diameter of the tube.
Use to set the define option as the only selection from the Bend Information part of the
Component Editor window, when using variable radius bends.
!!limitRadiusOptions = FALSE is the default and does not alter the multiplier list Setting it to true restricts it as shown.