SPOOL is
the pipework spooling module for AVEVA E3D™. It splits the pipework
design into logical sections (spools) ready for fabrication. The spool data can then be output as isometric drawings using ISODRAFT. Refer to the
ISODRAFT User Guide for further information.
Spool Drawings contain a number of complete Spool and Field elements, divided by Spool Breaks, where a SPOOL is defined as a run of piping components and tube that is connected during fabrication and a
FIELD is an individual or group of piping components that is connected on-site during the erection phase Spools cannot be split across Spool Drawings.
The Fabrication database structure descends from the World level (usually represented by the symbolic name
/*). The administrative levels below this (and their AVEVA E3D™ abbreviations) are
Department (ISODEP) and
Registry (ISOREG).
The database level below Registry (and its AVEVA E3D™ abbreviation) is the Spool Drawing (SPLDRG), which is the main operational unit of the database. Each Spool Drawing can represent a continuous network of piping components and tube within the overall piping design The Spools and Fields that make up the Spool Drawing are held directly below it in the database hierarchy.
The DESIGN database also descends from the World level, below which are the administrative sub-levels
Site and
Zone. In the case of piping design data, the lower administrative levels (and their AVEVA E3D™ abbreviations) are
Pipe (
PIPE) and
Branch (BRAN).