Supports
Customisation Guide
Framework Template Administration
:
Template Options
: Maximum Allowable Bore Sizes
Maximum Allowable Bore Sizes
Each support framework has the functionality to control the minimum and maximum pipe bore allowed for the template at the owning ZONE and the individual template STRU elements. Setting the minimum and maximum bore at the owning ZONE of the templates defines the minimum and maximum bore for the entire framework. It is also possible to set the minimum and maximum bore at the STRU for each individual framework template. For example, if the first template for FT09 is 60x06x8 angle, the :MdsMaxBore to is set to 100 and the :MdsMinBore to is set to 50, a pipe cannot be added to the support which is less than 50 or greater than 100. If the support is created on a pipe that is larger or smaller than this range, the template is not available upon creation and the Supports application attempts to select the next valid template in the list. The minimum and maximum bore must be set at the owning ZONE for the templates and must encompass the size range of all the individual templates below it.
1974 to current year.