Supports
Customisation Guide
Framework Template Administration
:
Template Options
: Vertical Section Overlap
Vertical Section Overlap
The vertical GENSEC is extended past the cross bar by the application overlap value, in order to weld the GENSEC together. In some circumstances the vertical member may need to be flush with the top of the cross bar. To achieve this, set the uda :MdsOlap value at the vertical GENSEC to OVERLAP and the uda :MdsOnum value to -100 (if the cross bar depth is 100).
The following example is the standard/default configuration with the :MdsOlap unset <default>.
The following example assumes a common template GENSEC size of 100x100x8 angle. The vertical GENSEC uda :MdsOlap value is set to OVERLAP and the :MdsOnum value is set to -100, (the depth of the cross bar being 100).
1974 to current year.