Framework Naming Conventions
Make sure each framework conforms to the following naming conventions. This enables the Supports application to navigate to the appropriate element and customise the application for both the MODEL and DRAW stages of support production. Failure to apply these naming conventions may cause the applications to fail to produce supports.
Type
Name format
Example
APPLDW
/SUPPORT/FRAMES/{name}
/SUPPORT/FRAMES/BS
APPLDA
/SUPPORT/FRAMES/{name}/DATA/{type}
/SUPPORT/FRAMES/BS/DATA/FT
ZONE
/SUPPORT/FRAMES/{name}/{frameworktype}
/SUPPORT/FRAMES/BS/FT09
STRU
/SUPPORT/FRAMES/{name}/{frameworktype}/{option}
/SUPPORT/FRAMES/BS/FT09/1
FRMW
/SUPPORT/FRAMES/{name}/{frameworktype}/{option}-FRMW1
/SUPPORT/FRAMES/BS/FT09/1-FRMW1
GENSEC
CROSSBAR
/SUPPORT/FRAMES/{name}/{frameworktype/{option}-BAR-1
/SUPPORT/FRAMES/BS/FT09/1-BAR-1
VERTICAL MEMBERS (if required)
/SUPPORT/FRAMES/{name}/{frameworktype}/{option}-V1 or V2
/SUPPORT/FRAMES/BS/FT09/1-V1
SUBS
/SUPPORT/FRAMES/{name}/{frameworktype}/{option}-SUBS1
/SUPPORT/FRAMES/BS/FT29/1-SUBS1
JLDATU
/SUPPORT/FRAMES/{name}/{frameworktype]/{option}-V1/S1
/SUPPORT/FRAMES/BS/FT09/10-V1/S1
PLDATU
/SUPPORT/FRAMES/{name/{frameworktype}/{option}-V1/S1/PLDAT
/SUPPORT/FRAMES/BS/FT09/10-V1/S1/PLDAT
FIXING
/SUPPORT/FRAMES/{name}/{frameworktype/{option}-V1/S1/IJOINT1
/SUPPORT/FRAMES/BS/FT09/10-V1/S1/IJOINT1
There are two zones for each of these framework types: FT03, FT04, FT14, FT15, FT18, and FT19. Each one is supplied with the suffix -H or -V. For example, /SUPPORT/FRAMES/BS/FT03H.
The suffix allows the orientation of members within the structure to be different when used with vertical or horizontal lines.