ISODRAFT
User Guide
Piping Components in ISODRAFT
: Reducers
Reducers
For both eccentric and concentric Reducers, the large (primary) and small (secondary) diameters will be shown in a message of the format LxS NS, where
L
arge and
S
mall are the nominal bore sizes.
An eccentric Reducer has its symbol drawn so as to show the orientation of its flat side, with the offset dimension listed under the size message.
Figure 6:14.
The annotation of reducers
Text information about the direction of the flat side of eccentric Reducers is not normally plotted, but the user can plot it using the alternative text facility. See the ATEXT command, and ATEXTs 243 and 283. For example, the text FLAT DOWN can be output by this method.