ISODRAFT
User Guide
Bolting
:
Bolt Specifications
: Bolts SHOP Flag
Bolts SHOP Flag
ISODRAFT takes the SHOP flag setting for bolts from the specification. The BOLT SPCOM should be defined with a SHOP selector column. If the SHOP flag is not specified, its setting defaults to FALSE. If the same bolt is to appear in both fabrication and erection lists, two SPCOMs must be defined which are the same up to a suffix delimiter, in the same way as for tube. Also, two flanges must be defined using the delimiter character, in order to reference the two bolts. The flanges will be totalled together if they are to appear in the same section of the material list.
Example:
TYPE
DEFAULT
NAME
PBOR0
SHOP
CATREF
DETAIL
MATXT
CMPREF
BLTREF
-
-
-
=
=
FLAN
*/FW100:TR
100
TRUE
/FWAAA
/D.FWA
/M.FWA
=0
/SBOL100T
FLAN
*/FW100:FA
100
FALS
/FWAAA
/D.FWA
/M.FWA
=0
/SBOL100F
. . .
TYPE
DEFAULT
NAME
PBOR0
SHOP
CATREF
DETAIL
MATXT
CMPREF
BLTREF
-
-
-
=
=
BOLT
*/BL100:TR
100
TRUE
/BLAAA
/D.BLA
/M.BLA
=0
/SBOL100T
BOLT
*/BL100:F
100
FALS
/BLAAA
/D.BLA
/M.BLA
=0
/SBOL100F
This example will give bolts in the same part of the material list (fabrication or erection) as the flange with SHOP TRUE or SHOP FALSE (default TRUE in this example).
The following example will give bolts in either list but total the flanges together in the fabrication list, by selecting the flange with BOLT SHOP or BOLT SITE. Note that item codes that are identical after removal of the specification name and the characters following the delimiter will be totalled together.
Example:
TYPE
DEFAULT
NAME
PBOR0
SHOP
BOLT
CATREF
DETAIL
MATXT
CMPREF
BLTREF
-
-
-
=
=
FLAN
*/FW100:SH
100
TRUE
SHOP
/FWAAA
/D.FWA
/M.FWA
=0
/SBOL100T
FLAN
*/FW100:SI
100
TRUE
SITE
/FWAAA
/D.FWA
/M.FWA
=0
/SBOL100F
. . .
TYPE
DEFAULT
NAME
PBOR0
SHOP
CATREF
DETAIL
MATXT
CMPREF
BLTREF
-
-
-
=
BOLT
*/BL100:TR
100
TRUE
/BLAAA
/D.BLA
/M.BLA
=0
/SBOL100T
BOLT
*/BL100:F
100
FALS
/BLAAA
/D.BLA
/M.BLA
=0
/SBOL100F
1974 to current year.