ISODRAFT
User Guide
Symbol Keys
: Symbol Attributes
Symbol Attributes
The attributes of ISODRAFT Symbol Templates are set in DRAW, where the symbol templates are defined. They are as follows:
SCale
val
Changes the size of the symbol without re-defining the coordinates of the plotted shape (100 = full size).
ORIentation
NONE
Specifies a symmetrical fitting which the flow direction is not relevant.
ORIentation
FLOW
Specifies a fitting for which the flow direction is important, such as check valves.
ORIentation REDUcer
Specifies a reducing fitting.
ORIentation FLANge
Specifies a fitting which begins with a flange; that is, one which is preceded by a gasket.
FLWA TRUE
Plots flow arrows on the symbol.
FLWA FALSE
Suppresses flow arrows.
DIMEnsion ON
Plots dimensions alongside the symbol.
DIMEnsion OFF
Suppresses the plotting of dimensions.
Fill
Enables default and user-defined symbols to be drawn as filled polygons.
User-defined symbols based on the following SKEYs and defined with ORI FLAN or ORI REDU will be automatically flipped to fit in with the pipeline component sequence.
GTYPE
SKEY
Description
CAP
All
All caps
FLAN
All
All flanges
LJSE
All
All lap joints stub ends
PCOM
PL
Plug
REDU
All
All reducers
User-defined symbols based on the following SKEYs and defined with ORI FLOW will be automatically flipped depending on the flow direction.
GTYPE
SKEY
Description
INST
DR
Rupture disk
INST
XV**
Pressure reducing valve
PCOM
TU**
Tundish (funnel)
VALV
CK**
Check valve
VALV
VX**
Pressure reducing valve
VENT
RD
Rupture disk
1974 to current year.