ISODRAFT
Reference Manual
Transfer Data to the COMPIPE Module
: Limitations
Limitations
Itemcodes containing the / character
The slash (/) character is used by default as a delimiter within the Intermediate Data File (transfer file) between itemcodes, short codes and COMPIPE Spec names. Therefore, if itemcodes are to contain slash characters (e.g. in the case of ITEMCODE LENGTH LONG where the specification name is included), an alternative delimiter must be set as ATEXT 299.
Note:
It is the itemcode after SPEC name and trailing delimiter characters have been removed that is important. Since the slash character is often used within AVEVA E3Dā¢ names, ISODRAFT will automatically set Atext 299 to the tilde (~) character when COMPIPEFILE is set. This can then be changed if required, e.g. use ATExt 299 ā:ā.
1974 to current year.
AVEVA Solutions Limited and its subsidiaries. All rights reserved.