This Atext is blank by default. It can be used to produce a message at any pipe end whose HCON or TCON is not one of the recognised ends; i.e. not SCRD, VENT, DRAN, OPEN or CLOS.
|
|
This Atext is blank by default. If it is set to any word (e.g. FLAT), eccentric reducers will have the orientation of their flat side indicated by that word.
|
|
Message pointing to any place in the pipe where the specification changes if Dimensiontype is in force (refer to SPECBREAK command). The names of the old and new specifications are automatically included. (Refer to Atext 232.)
|
|
Message pointing to any place in the pipe where the specification changes if Dimensiontype is in force (refer to SPECBREAK command). The names of the old and new specifications are automatically included.
|
|
Message pointing to any place in the pipe where the specification changes if Dimensiontype is in force (refer to SPECBREAK command). The names of the old and new specifications are automatically included.
|
|
Message pointing to any place in the pipe where the specification changes if Dimensiontype is in force (refer to SPECBREAK command). The names of the old and new specifications are automatically included.
|
|
Note:
|
Atext 243 produces the flat side message for reducers in orthogonal piping and Atext 283 is used for reducers in non-orthogonal piping.
ISODRAFT indicates the flat side of an eccentric reducer by default only when the reducer is skewed. By using Atexts 243 and 283, the user can have the flat side indicated, or not, for skewed-only or all reducers. |