Select Extra Inline Equipment in the
Categories drop-down list and then
Flat Low Vel’ Terminal in the
Available Type drop-down list to display the
Flat LV Terminal window:
The Flat LV Terminal window default is a standard stock size, but can be changed by you using the following two methods:
In the Name(Ref) field, input the name of the
HVAC component.
To choose from the standard stock sizes available from the HVAC Catalogue, in the
Stock Size drop-down list, click the size for the HVAC component.
In the Handling drop-down list, click the
Handling of the Flat LV Terminal.
Specify a type of joint to use for the Arrive Joint and
Leave Joint. Refer to
Create/Modify HVAC Component for a detailed description.
In the Direction X specify the axis that should be used. Valid axes are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up).
The Face Clash Volume field is pre-populated with the obstruction volume associated with the
Flat LV Terminal and the ducting.
Click Defaults to reset all the fields back to when the
Flat LV Terminal window was opened.
Click Fit to orientate the
Flat LV Terminal to automatically match the outlet (p-leave) of the previous piece of
HVAC to the inlet (p-arrive) of the next piece.
Click OK to create the
Flat LV Terminal component and close the
Flat LV Terminal Window. You will be returned to the
HVAC Window.
Click Cancel to discard all the field changes and close the
Flat LV Terminal window.