HVAC

Components : Inline Plant Equipment : Circular Control Damper
The task of creating an HVAC Component is initiated from the HVAC Window.
Select Inline Plant Equipment in the Categories drop-down list and then CIRCULAR, Control Damper in the Available Type drop-down list to display the Control Damper window:
Specify a type of joint to use for the Arrjoint (Arrive Joint) and Leajoint (Leave joint). Refer to Create/Modify HVAC Component for a detailed description.
After selecting the type of joint to use for the Arrive Joint and Leave Joint you must enter the Handle Direction.
In the Handle Direction specify the axis that should be used. Valid axes are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up).
The Clash Vol fields will be pre-populated with the obstruction volumes associated with the rectangular flanged FD component and the ducting, but can be changed by you.
In the Position list, select Connect or Unchanged:
Click Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
Click Unchanged (default when Modify is selected) - positions the component at the co-ordinates 0.00.
Note:
Unchanged is usually used, when Modify is selected, it does not connect the component but positions it at 0.00, in effect in a floating position.
Click Defaults to reset all the fields back to when the Control Damper window was opened.
Click Fit to orientate the Control Damper to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.
Click OK to create the Control Damper component and close the Control Damper Window. You will be returned to the HVAC Window.
Click Cancel to discard all the field changes and close the Control Damper window

1974 to current year. AVEVA Solutions Limited and its subsidiaries. All rights reserved.
AVEVA Logo