HVAC

Components : Circular : Mitred Offset
The task of creating an HVAC Component is initiated from the HVAC Window.
Select Circular in the Categories drop-down list and then Mitred Offset in the Available Type drop-down list to display the Mitred Offset window:
To visualise how the dimensions equate to the actual piece of HVAC, click Picture to display a detailed drawing for Mitred Offset.
Specify a type of joint to use for the Arrive Joint and Leave Joint. Refer to Create/Modify HVAC Component for a detailed description.
After selecting the type of joint for the Arrive Joint and Leave Joint you must enter the Offset Direction.
In Offset Direction enter the direction of the Offset relative to the Point of Origin. Valid directions are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up).
In the Position list, select Connect or Unchanged:
Click Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
Click Unchanged (default when Modify is selected) - positions the component at the co-ordinates 0.00.
Note:
Unchanged is usually used, when Modify is selected, it does not connect the component but positions it at 0.00, in effect in a floating position.
Click Defaults to reset all the fields back to when the Mitred Offset window was opened.
Click Fit to orientate the Mitred Offset component to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.
Click OK to create the Mitred Offset component and close the Mitred Offset Window. You will be returned to the HVAC Window.
Click Cancel to discard all field changes and close the Mitred Offset window.