HVAC
Administrator Guide
Insulation Specifications
Insulation Specifications
Insulation is applied at Branch level by setting of the ISPEC attribute. There is currently one insulation specification, named /CADCHVACISPEC, available in the HVAC application. However, if a User Defined Insulation specification is required it will be necessary for the HVAC Administrator to create a similar specification in a CATA database:
new spec /MyISpec copy /CADCHVACISPEC rename /CADCHVACISPEC /MyISpec
The SPWL will have a PURP HVAC and the SPEC will have a PURP INSU
The SPEC will have the MATREF set to a material in the properties database that has a valid material density.
The database structure for the insulation is as follows:
SPWL
Purp HVAC
SPEC
Purp INSU
Question TYPE
Matref /MyInsulationMaterial
SELE
QUES TEMP
TANS 'INSU'
TDEF 'NONE'
SELE
DESC '1"'
ANSW 24
MAXA 26
QUES PBOR
TDEF 'NONE'
SPCO /MyISpec/INSU25
MAXA 10000
CATREF /INSU25
SELE
DESC '1.1/4" - For when in imperial units
ANSW 29 -- for 30mm insulation
MAXA 31
QUES PBOR
TDEF 'NONE'
SPCO /MyISpec/INSU30
MAXA 10000
CATREF /INSU30
Etc…
The CATREF element also must exist and can be defined by the administrator:
SCOM /INSU25
PARAM 50
SCOM /INSU30
PARAM 60
By creating these Cats&Specs elements this means that:
•
Insulation Spec and thicknesses will appear on the Create Branch form
•
Insulation weight will be used in weight calculations
•
Insulation can be shown graphically by using IPARAM[1] in the catalogue geometry. (Actually IPARAM[2] could also be used if required for 2 level insulation but the standard catalogue has not included this in its geometry).