HVAC
Administrator Guide
User Defined Components
:
Tutorial Style Exercise
: Edit the Geometry Set
Edit the Geometry Set
Again, the geometry set *-GMSE was inherited from the copied component, but it is now easy to modify the Primitive elements to be positioned using the new parameters.
In MODEL at the newly created Threeway element, use GOTO GMREF to navigate to the GMSE element and view it in the Members list.
Reminders:
•
Name all elements using setstar* to aid recognition
•
Normal representation lev 0 - 10
•
Negatives representation lev 9 - 10
•
Flanges representation lev 6 - 10
•
Insulation representation lev 7 - 10
•
Remember to check these before the item is finished. It is suggested to use reporter to check these and a macro to make sure they are all corrected.
1974 to current year.
AVEVA Solutions Limited and its subsidiaries. All rights reserved.