HVAC
Administrator Guide
DRAW Sketches
:
Assembly Tables and Endpoint Tables
: Log Messages
Log Messages
To write any message to the Log Data from any PML function use :
!!hvacSketchesLog('Text of your choice')
To clear the messages from the Log Data use:
!!hvacSketch.emptyLogData()
To write to the log File use:
!!hvacSketch.logFile
= object FILE('%AVEVA_DESIGN_USER%/hvacSketches.txt')
!!hvacSketch.openLogFile()
!!hvacSketch.writeLogFile()
- This write the contents of .logData to the .logFile
!!hvacSketch.closeLogFile()
1974 to current year.