DRAW Reference Manual
ISODRAFT Symbols
:
Create ISODRAFT Symbol Templates
: Attributes of ISODRAFT Symbol Templates
Attributes of ISODRAFT Symbol Templates
The attributes of ISODRAFT Symbol Templates that are additional to the attributes of normal symbol templates are:
SKEY
Symbol key: the SKEY of the new Symbol. If this attribute is set to the SKEY of an existing symbol, the existing symbol is redefined. You can use wildcards to define a symbol for several similar SKEYs. Refer to
Wildcards in SKEYs
for further information.
BKEY
Base symbol key. If a new SKEY is being defined, the BKEY must be set to a standard SKEY. Wildcards can be used. Refer to
Wildcards in SKEYs
for further information.
SCALe
value
Changes the size of the symbol without redefining the coordinates of the plotted shape (100 = full size).
SPINdle
Spindle symbol key. If this attribute is set, the Symbol Template includes a spindle symbol. Refer to
Symbol Keys
for further information. Default NONE.
ORIN NONE
Specifies a symmetrical fitting which the flow direction is not relevant
ORIN FLOW
Specifies a fitting for which the flow direction is important, for example, check valves
ORIN REDUCER
Specifies a reducing fitting
ORIN FLANGE
Specifies a fitting which begins with a flange; that is, one which is preceded by a gasket
FLWArrow TRUE
Plots flow arrows on the symbol
FLWArrow FALSE
Suppresses flow arrows
DIMEnsion TRUE
Plots dimensions alongside the symbol. Default
DIMEnsion FALSE
Suppresses the plotting of dimensions
INSL TRUE
Insulation representation on symbol if specified. Default
INSL FALSE
Insulation representation suppressed
TRCG TRUE
Tracing representation on symbol if specified. Default
TRCG FALSE
Tracing representation suppressed
FILL TRUE
Symbol to be filled
FILL FALSE
Symbol not filled. Default