Model Reference Manual
Clash Detection
:
Approving Clashes
: Adding Clashes to the Approval List
Adding Clashes to the Approval List
Keywords:
APPROVE
Description:
Adds clashes to the approval list in any of the following ways:
•
By specifically identifying a known clash between two named items
•
By specifically identifying a known clash by means of its reference number in the latest clash report
•
By generally referring to actual or potential clashes between named items; either before or after running a check to see what clashes exist
•
By specifying actual or potential clashes within a single named element
Approved clashes will be omitted from clash reports regardless of which way round the interfering items are specified in the obstruction list and the check list in subsequent clash-checking runs.
Examples:
APPROVE HS TOUCH BOX1 OF /EQUI1 WITH /GASK1 OF /BRAN2
Approves hard/soft touch between named items (and any lower level touches; e.g. HI, SS etc.)
APPROVE 5
Approves the fifth clash in most recent clash report
APPROVE SIGNIF 5
Approves fifth clash in most recent clash report at significant element level, rather than at primitive level; where the significant elements are:
Sites, Zones, Pipes, Branches, Equipments, Structures, Substructures, Hangers, Restraints, Ptracks, Frameworks, and Subframeworks
APPROVE II CLASH /BRAN1-1 WITH /ZONE.EQUIP
Approves all Insulation/Insulation clashes between any elements below /BRAN1-1 and any elements below /ZONE.EQUIP
APPROVE /ZONE.EQUIP WITH /ZONE.STEELW
Approves
all
types of clash between members of the named zones
APPROVE HS CLASH /ZONE.EQUIP WITH /ZONE.EQUIP
Approves all hard/soft clashes between members of /ZONE.EQUIP (and any lower level clashes, touches or clearances)
Command Syntax:
>-- APProve -+- <cltyp> -+- CLAsh -----.
| | |
| |- TOUch -----|
| | |
| |- CLEarance -|
| | |
| ‘-------------|
| |
|- NP --------------------+- <clid> -+-- WITh --.
| | |
| ‘----------+- <clid> -->
|
|--- SIGnificant ---. .------<-------.
| | / |
‘-------------------+---*--- clash_no ---+-->
where <cltyp> (clashing type) is one of the following:
HH HS HI SS SH SI II IH IS NP
and <clid> (clashing item identifier) is
>---+--- ILEAve ---.
| |
|--- IARRIVE --|
| |
|--- HEAD -----|
| |
|--- TAIL -----+--- TUBe ---.
| | |
| |--- ROD ----|
| | |
| ‘------------+--- OF -----.
| | |
| |--- FROM ---|
| | |
| |--- TO -----|
| | |
| ‘------------+
| |
‘----------------------------------------+--- <gid> --->
Note:
Clashing type H(ard) automatically includes S(oft) and I(insulation). CLASH automatically includes TOUCH and CLEARANCE.