Model Reference Manual
Clash Detection
:
Reporting Without Further Clash Checking
: Suppressing Clash Repetition in Reports
Suppressing Clash Repetition in Reports
Keywords:
REPORT FIRST
Description:
When used before an OUTPUT command, the REPORT FIRST option allows the user to generate a sequence of reports from a single set of clash data such that each clash is reported once only throughout the complete sequence.
Example:
REPORT FIRST ALL
OUTPUT /ZONE.PIPES
OUTPUT /ZONE.STEELW
Assume a clash check has just been run which includes piping and steelwork items among the elements checked. Then this sequence generates two separate reports; the first (from OUTPUT /ZONE.PIPES) shows all clashes involving pipework elements, including those between pipework and steelwork; the second (from OUTPUT /ZONE.STEELW) shows all clashes involving steelwork elements except those which were included in the first report (i.e. the second report omits clashes between pipework and steelwork.
Command Syntax:
>--- REPort FIRst ALL --->
1974 to current year.