Model Reference Manual
Clash Detection
:
Reporting Without Further Clash Checking
: Generating a Report from Existing Clash Data
Generating a Report from Existing Clash Data
Keywords:
OUTPUT
Description:
The report generated in response to an OUTPUT command has exactly the same format, determined by any current reporting options which have been set, as that generated in response to a CHECK command. The difference is that the check options, touch and clearance values, obstruction list etc. which apply to the Output report are those current
when the clash run was carried out
; these need
not
be current when the OUTPUT command is given.
Examples:
OUTPUT CLASHES /ZONE1.PIPES
OUTPUT /PUMP1 /PUMP2 /VESS2
OUTPUT /GROUP.MOD2
OUTPUT LEAVE TUBE FROM /FLAN2 IARRIVE TUBE TO /VALV5
These commands output reports of known clashes involving the specified items in each case
OUTPUT
Outputs a complete report of all clash data currently held in memory
Command Syntax:
>--- OUTput ---+--- CLAshes ---.
| |
‘---------------+--- <clid> --->
where <clid> (clashing item identifier) is
>---+--- ILEAve ---.
| |
|--- IARRIVE --|
| |
|--- HEAD -----|
| |
|--- TAIL -----+--- TUBe ---.
| | |
| |--- ROD ----|
| | |
| ‘------------+--- OF -----.
| | |
| |--- FROM ---|
| | |
| |--- TO -----|
| | |
| ‘------------+
| |
‘----------------------------------------+--- <gid> --->