Model Reference Manual
Clash Detection
:
Checking For Clashes
: Running a Full Component Check
Running a Full Component Check
Keywords:
CHECK
Description:
The CHECK command initiates a full two-stage check for clashes between specified items (the check list) and the current obstruction list.
Examples:
CHECK ALL
Checks all items in the design model (within any restrictions defined as in Sections 3.3 to 3.9) against the obstruction list.
CHECK /ZONE1.PIPES
CHECK /PUMP1 /PUMP2 /VESS2
CHECK /GROUP.MOD2
CHECK LEAVE TUBE FROM /FLAN2 IARRIVE TUBE TO /VALV5
Checks only specified items against the obstruction list.
Command Syntax:
.-----<------.
/ |
>--- CHEck ---*--- <clid> ---+---.
| |
‘--- ALL ---------+--->
where <clid> (clashing item identifier) is
>---+--- ILEAve ---.
| |
|--- IARRIVE --|
| |
|--- HEAD -----|
| |
|--- TAIL -----+--- TUBe ---.
| | |
| |--- ROD ----|
| | |
| ‘------------+--- OF -----.
| | |
| |--- FROM ---|
| | |
| |--- TO -----|
| | |
| ‘------------+
| |
‘----------------------------------------+--- <gid> -->