Model Reference Manual

Data Consistency Checking : Diagnostic Messages from Data Consistency Checks : Structure-Specific Diagnostics
SC010 Catref/Specref of struc_elem unset
SC020 Pline word of struc_elem does not exist
SC030 POSL of struc_elem unset
SC040 POSL of struc_elem_1 refers to non-existent Pline in struc_elem_2
SC070 struc_elem is not connected
SC080 Incompatible GTYPE of struc_elem: word_1 in Design, word_2 in Catalogue
SC090 Jline of struc_elem unset
SC100 INCOMPATIBLE ROD DIAMETER BETWEEN name AND name FOR HANGER HEAD AND TAIL
SC120 Catref/Specref of struc_elem refers to a non-existent element
SP010 Discrepancy between ends of Jlines: word of struc_elem_1 and word of struc_elem_2
SP020 Positions of struc_elem_1 and struc_elem_2 misaligned
SP030 struc_elem_1 lies off the beginning or end of owning Section struc_elem_2
SD010 Normal to Cutting plane word of struc_elem_1 is perpendicular to Neutral axis of struc_elem_2
SD020 Normal to Cutting plane word of struc_elem_1 is perpendicular to Origin plane of struc_elem_2
SD030 Cutting planes word of struc_elem_1 and word of struc_elem_2 misaligned
SD040 Check Beta angles of struc_elem_1 and struc_elem_2
SD060 Normal to cutting plane word of struc_elem not in general direction of
other end of section
SE010 Struc_elem diverges from logical model: eccentricity out of range
SE020 Struc_elem diverges from logical model: angle out of range
SL010 Length of struc_elem is out of range. Actual length is ...
SL020 Logical length of struc_elem is zero

1974 to current year. AVEVA Solutions Limited and its subsidiaries. All rights reserved.