Model Reference Manual
Data Consistency Checking
: Specify User-Defined SKEYs Acceptable in Data Checks
Specify User-Defined SKEYs Acceptable in Data Checks
The symbol used by ISODRAFT to represent a particular piping component on an isometric drawing is determined by its
symbol key
(SKEY attribute setting). (Refer to
Symbol Keys
l for a full explanation of this concept.)
Keywords:
TOLERANCE CATALOGUE SKEY
Description:
When a data consistency check is carried out, the SKEY (if any) for each component is checked to see if it is of a standard type. This syntax lets the user specify user-defined SKEYs so that they do not generate errors during data consistency checks.
Example:
TOL CATA SKEY ’JIM’ ’FRED’ ...
Components with the user-defined SKEYs ‘JIM’, ‘FRED’ etc. will not generate errors caused by unrecognised SKEYs.
Command Syntax:
.--------.
/ |
>-- TOLerance CATAlogue SKEY --*--
text
---+-->
Note:
Text
is case-sensitive; SKEYs are usually, but not necessarily, uppercase characters.
Querying:
>-- Query TOLerance CATAlogue SKEY -->
Outputs current list of user-defined SKEYs to be ignored during data consistency checks.
1974 to current year.
AVEVA Solutions Limited and its subsidiaries. All rights reserved.