Model Reference Manual

Structural Design Using Catalogue Components : Representing Curved Beams and Walls : Positioning Items Relative to Generic Sections
The Justification Line Datum (JLDATUM) element defines a frame of reference for its members based on the p-line system of its owning GENSEC. Each JLDATUM can own a set of P-line Datum (PLDATUM) elements, each of which defines a frame of reference for its members based on a nominated p-line of its owning JLDATUM. By manipulating a JLDATUM, all of its member PLDATUMs can be manipulated as a group, together with any Fixings owned by the latter.
TPREF and HPREF specify, by reference to POINSPs of the parent GENSEC (more strictly, its Spine), the start and end points, respectively, between which interpolated positions will be calculated. If both are unset, TPREF defaults to start of the GENSEC and HPREF defaults to the end of the GENSEC. If only one is set, the other defaults to the next POINSP in the appropriate direction.
PKDI specifies a point, as a proportion of the distance from TPREF to HPREF, from which ZDIST is to be measured. The default setting is 0, giving a position at TPREF. If PKDI is less than 0 or greater than 1, the position will be on the preceding or following segment, respectively, of the Spine.
ZDIST specifies the distance of the JLDATUM origin from the PKDI point, as measured along the Justification Line (JUSL) or NA p-line of the GENSEC.

1974 to current year. AVEVA Solutions Limited and its subsidiaries. All rights reserved.