Automatic Pipe Routing
:
Refining the Automatic Pipe Routes
: Spreading Pipes about the Rack
Spreading Pipes about the Rack
Keywords:
SPREAD
Description:
SPREAD moves the pipes laterally across the rack in the SDIR direction to give the specified clearance. The default clearance is 50mm between pipe walls on the same centreline.
Examples:
SPREAD /PIPES
Spreads the pipes in /PIPES about the designated rack
SP /PIPES WW 100
Spreads the pipes such that the wall-to-wall clearance is 100mm
SP /PIPES WF 4IN
Spreads the pipes such that the diameter of Flanges will be considered as part of the calculation. In this case, the distance between a Flange o/d and its adjacent pipe wall, will be a minimum of 4 inches.
SP /ZONE1 FF 75
Spreads the pipes such that two opposing Flange diameters will have a minimum clearance of 75mm. Pipes with no Flanges would have a wall-to-wall clearance of 75mm.
SP ALL
Repeat previously defined order sequence (for example, on a subsequent rack).
Command Syntax:
>-- SPread --+-- WW ---.
| |
|-- FF ---|
| |
|-- WF ---|
| |
|-- ALL --|
| |
‘---------+-- <uval> --. .-----<----.
| | / |
‘------------+-*-- <sgid> --+-->