Model Reference Manual
Automatic Pipe Routing
:
Refining the Automatic Pipe Routes
: Defining the Base Direction
Defining the Base Direction
Keywords:
BASE
Description:
This is the direction in which the pipes will be moved in order to sit on the rack. By default, this is the direction of the smallest side of the PVOL.
Example:
BASE W
Sets the base direction to be West. (This should always be perpendicular to the spread direction.)
Command Syntax:
>-- BAse <bdir> -->