Model Reference Manual
Piping, Ducting and Cable Trays
:
Component Clearance Positioning
: Component Clearance Either Side
Component Clearance Either Side
Keywords:
CLEARANCE INFRONT BEHIND
Description:
This command places the current Component on the constrained centreline at a specified clearance in front of or behind a fixed design object. If the Arrive or Leave point of the referenced object is used, then the Tube cross-section at this point is considered rather than the full item geometry.
Examples:
CLEAR BEHIND /WALL
The Component will be placed on the constrained centreline with zero clearance on the ‘far side’ of the specified element (see
Figure 8:26.: Component clearance either side of a fixed object
).
CLEAR 1200 INF PL OF NEXT
The Component will be placed on the constrained centreline with 1200 clearance ‘this side’ of the Tube emerging from the Component’s Leave point (see
Figure 8:26.: Component clearance either side of a fixed object
).
Command Syntax:
>-- CLEArance --+-- <uval> --.
| |
‘------------+-- INFront --.
| |
‘-- BEHind ---+-- <gid> ---.
| |
|-- <marke> --|
| |
‘-- <bpos> ---+-->
Querying:
>-- Query <marke> --+-- POSition --.
| |
|-- BOP -------|
| |
‘-- TOP -------+-- WRT --.
| |
‘-- IN ---+-- <gid> -->
Figure 8:26.
Component clearance either side of a fixed object
1974 to current year.