Component Clearance Positioning
: Clearance from the Previous Component
Clearance from the Previous Component
Keywords:
CLEARANCE
Description:
This command places the Component at a specified clearance from the previous Component on the constrained centreline. The whole geometry of both Components is considered.
Example:
CLEA 500
The Component will be placed on the constrained centreline 500 clear of the Previous Component (see
Figure 8:25.: Clearance from a Previous Component
).
Command Syntax:
>-- CLEArance <uval> -->
Querying:
>-- Query <marke> --+-- POSition --.
| |
|-- BOP -------|
| |
‘-- TOP -------+-- WRT --.
| |
‘-- IN ---+-- <gid> -->
Figure 8:25.
Clearance from a Previous Component