Model Reference Manual
Piping, Ducting and Cable Trays
:
Standard Component Attributes
: Component Arrive and Leave Attributes
Component Arrive and Leave Attributes
Keywords:
ARRIVE LEAVE
Description:
This command sets the attributes that control which p-points are the Arrive and Leave for a Component. It is usual to set those attributes before Selection and Positioning as they can define:
•
The automatic Selection Parameters for that item (particularly REDUCERS)
•
The centreline Logical Route that will affect positioning and orientation of the Component.
However, as the p-point details for Arrive (PA) and Leave (PL) are obtained from the Catalogue, these may only be used or interrogated
after
Selection.
Example:
ARR 2 LEAV 1
The Logical Route will Arrive at P2 and Leave at P1 of the Component.
ARR 3 LEAV 2
The Logical Route will Arrive at P3 and Leave at P2 of the Component.
Note:
Default is Arrive 1, Leave 2.
Command Syntax:
>--+-- ARRive --.
| |
‘-- LEAve ---+-- P --------.
| |
‘--
integer
--+-->
1974 to current year.
AVEVA Solutions Limited and its subsidiaries. All rights reserved.