Model Reference Manual
Piping, Ducting and Cable Trays
:
Selecting Component and Tube Details from Specifications
: Selecting ‘Out-of-Specification’ Components
Selecting ‘Out-of-Specification’ Components
Keywords:
SELECT SPEC
Description:
If an ‘out-of-specification’ Component is required, this can be Selected using the SELECT WITH SPEC command. This command uses the stated Specification rather than the default Specification. Other Headings necessary to specify which ‘out-of-specification’ item is required can be given in the same command.
Examples:
SEL WI SPEC /A3AH
The current element will be Selected from the given Specification using the default choice.
SEL WI SPEC /A3AH STYPE CTRL
The current element will be Selected from the given Specification using the default choice except for STYPE.
Note:
The Leave Tube will be selected from the default (Branch) Specification in all cases.
Command Syntax:
.-----<-----.
/ |
>-- SElect WIth SPec <gid> --* |
|-- <wivl> ---|
| |
|-- <wiwor> --’
|
|-- <gid> -->
|
‘-->
<wivl> and <wiwor> are explained in
Standard Syntax Graphs
.
Querying:
.-----<-----.
/ |
>-- Query SPECification --*-- <qspci> --+-->
<qspci> is explained in
Standard Syntax Graphs
.
>-- Query --+-- SPRef --.
| |
‘-- TUbe ---+-->