Database Management
Reference Manual
Attributes
: Real Attributes of Physical Quantities
Real Attributes of Physical Quantities
Real attributes can be purely numeric, but often they may be representing physical quantities. The type of a physical quantity is its (physical) dimension.
Attributes of physical quantities are consistently stored in the database in defined database units, irrespective of the current working units, or of the units of any value entered by you. The whole system operates on the expectation that all stored values of physically dimensioned quantities are in their relevant standard database units.
The following table lists the dimensions understood by the system giving:
Their name (or description) recognised by the system,
The assigned hashcode,
The database storage units.
Supported standard units for the quantity
For example attributes of length have a hash code of DIST are stored in mm and other standard units include inch, cm, ft, metre etc.
Name of Dimension
HashCode/Word
Database Units
Other Specific Units
Comments
AbsPressure
ABSP
pascal
bar atm PSI torr mmHg inHg
pressure may be absolute or gauge
Acceleration
ACCL
m/s2
ActualPower
ACTPOW
V.A
Angle
ANGL
degree
grade arcmin arcsec
AngularAcceleration
ANGCCE
rad/s2
AngularFrequency
ANGF
deg/s
rpm rps rph angFreqHertz
AngularMomentum
ANGM
N.m.s
Area
SQDI
mm2
acre hectare
AreaPerLength
AREALE
m2/m
AreaPerLength
Bore
BORE
mm
in
Range of bore units limited to mm and inch (and Finch)
CableSize
CABL
kcmil
cirmil circmms
CalorificValueMole
CALVQ
J/Mol
CalorificValueVolume
CALVV
J/m3
Capacitance
CAPA
farad
Charge
CHAR
coulomb
Conductance
COND
siemens
mho
Content
PCUD
mm-3
ConvertiblePressure
PRESC
cpascala
cpascalg cbarg catmg cpsig ctorrg cmmHgg cinHgg cbara catma cpsia ctorra cmmHga cinHga osia inHgaAtSixtyDegF mmHgaAtSixtyDegF inWateraAtSixtyDegF inWateraAtFourDegC ftWateraAtSixtyDegF ftWateraAtFourDegC ata
Currency
CURY
USD
GBP EUR
Current
CURR
ampere
CurrentDensity
CURITY
A/m2
Density
DENS
kg/m3
DensityMANDB
MAND
kg/mm3
densities stored in MANU database
EffectiveHeatCapacity
EFFCAP
J/m/K
ElectricChargeDensity
ELECSI
C/m3
ElectricConductivity
CNDT
S/m
ElectricField
EFLD
V/m
ElectricFluxDensity
ELEFSI
C/m2
EMF
EMF
volt
Energy
ENER
kWh
joule BTU calorie calorieit BTUit chu chuAtFifteenDegC
EnergyDensity
EDEN
J/kg
Entropy
ENTR
J/K
Equivalence
EQUIVA
equivalent
EquivalenceFlow
EQULOW
equiv/s
EquivalencePerVolume
EQPRME
equiv/m3
FlowRateMolePerLength
SQPTD
Mol/s/m
FlowRateVolPerRpm
FRVPR
Force
FORC
newton
pdl dyne kgf lbf
FoulingFactor
FFAC
m2.K/W
Frequency
FREQ
hertz
freqRpm freqRps freqRph
GaugePressure
GAGE
pascal
bar atm PSI torr mmHg inHg
pressure may be absolute or gauge
HeatCoefficientArea
HEAREA
W/K
HeatFluxLinear
HEAEAR
W/m
HeatingValue
HVAL
J/m3
HeatOfReaction
HEAION
J/m3/h
HeatTransferCoeff
HTRA
W/m2/K
Illuminance
ILLUMI
lux
Impedance
IMPE
ohm
Inductance
INDU
henry
Inertia
INER
kg/m2
InversePressure
INVURE
pascal-1
InverseTemperature
INVRAT
kelvin-1
KinematicViscosity
KVIS
m2/s
Stoke
Length
DIST
mm
m in ft cm km mile yard micron thou angstrom
LinearDensity
PDIS
mm-1
Luminance
LUMNCE
cd/m2
LuminousFlux
LUMLUX
lumen
LuminousIntensity
LUMI
Candela
MagFieldIntensity
MFIN
A/m
MagFluxDensity
MFXD
tesla
MagneticFlux
MGFX
weber
Mass
MASS
kg
gram tonne lb oz longTon shortTon cwt longCwt shortCwt ozt grain stone
MassFlow
MFLO
kg/s
MassFlux
MASLUX
kg/s/m2
MassPerArea
MAPEA
kg/m2
MassPerEnergy
MAPGY
kg/J
MassReactionRate
MARETE
kg/s/m3
MolarConcentration
MOLONC
Mol/m3
MolarEntropy
MOLOPY
J/Mol/K
MolarFlow
MOLLOW
Mol/s
MolarMass
MOLASS
kg/Mol
MolarPermeability
MOLITY
MolarReactionRate
MOLATV
Mol/m3/s
MolarReactionRateMass
MOLATM
Mol/kg/s
MolarVolume
MOLUME
m3/Mol
MoleFluxDensity
MOLATA
Mol/m2/s
MolePerMass
MOLALY
Mol/kg
Momentum
MOME
N.s
Noise
NOIS
DecibelA
Permeability
PMBT
H/m
Permittivity
PMTT
F/m
pH
PH
pH
Power
POWE
kW
hp watt
PowerPerArea
POPEA
W/m2
PowerPerVolume
POWUME
W/m3
Pressure
PRES
pascal
bar atm psi torr mmHg inHg osi inHgAtSixtyDegF mmHgAtSixtyDegF inWaterAtSixtyDegF inWaterAtFourDegC ftWaterAtSixtyDegF ftWaterAtFourDegC mmWaterAtSixtyDegF mmWaterAtFourDegC at
PressurePerDistance
PRPEST
Pa/m
PressurePerTemperature
PRPEMP
Pa/K
PressureRate
PREATE
Pa/s
Radiance
RADNCE
RadiantIntensity
RADITY
W/sr
RadiationDose
RDOS
sievert
rem gray raddose
Radioactivity
RADY
Bq
curie
RadioactivityConc
RADONC
Bq/m3
Ratio
RATIO
Ratio
pc ppm ppb
ReactivePower
REAC
VAreac
Resistivity
REST
ohm/m
RotationalStiffness
STFR
N.m/rad
SecondMomentOfArea
SMOFA
metre4
SolidAngle
SANGL
steradian
SolventPermeability
SOPETY
kg/m2/s/Pa
SpecFuelelConsumptionVol
SPFUNS
m3/J
SpecHeatCapacity
SHCP
J/kg/K
SpecificRadioactivity
SPVITY
Bq/g
SpecificSurfaceMass
SPEASS
m2/kg
Speed
SPEE
m/s
knot
Stiffness
STIF
N/m
SubstanceQuantity
SUBQ
Mole
lbMole stdcubicfoot stdcubicmeters
SurfaceDensity
PSQD
mm-2
Temperature
TEMP
degC
degF kelvin degRan
TemperatureGradient
TPDI
degC/mm
TemperatureRate
TEMATE
K/s
TemperatureVolumePerMole
VOLPTQ
ThermalConductivity
TCON
W/m/K
ThermalExpansionCoeff
THENCO
degC-1
ThermalResistance
TRES
K/W
Time
TIME
second
min hr day month week year
Torque
TORQ
N.m
UnitMass
UMAS
kg/mm
ViscosityDynamic
VISC
Pa.s
poise
VolHeatTransferCoeff
VOLEFF
W/m3/K
Volume
CUDI
mm3
litre ImpGal USGal bbl Mbbl MMbbl grt ImpQrt USQrt USDryQrt ImpPint USPint USDryPint ImpFloz USFloz USDryGal
VolumetricFlow
VFLO
m3/s
MSCubicFeetDay
None
NONE
numerical real attribute
WORD
WORD
used in assigning parameter dimensions etc.
Parameter
UNIPAR
used for parameter attributes
1974 to current year.
AVEVA Solutions Limited and its subsidiaries. All rights reserved.