Database Management
Reference Manual
Output Syntax
:
Some Examples of Output
: PASS Option
PASS Option
Optionally output 1st pass or 2nd pass only
Output syntax 1st pass only
OUTPUT PASS 1 /EQUIP
Output
INPUT BEGIN
NEW ZONE /EQUIP
FUNC 'Equipment - above grade'
PURP EQUI
NEW EQUIPMENT /E1301
POS E 2850 N 5660 U 1470
UCOFG E 0 N 0 U 0
BUIL true
DSCO unset
PTSP unset
INSC unset
NEW CYLINDER
POS E 0 N 3299 U 0
ORI Y is D and Z is N
LEVE 0 4
DIAM 960
HEIG 6598
Output Syntax 2nd Pass Only
OUTPUT PASS 2 /EQUIP
Output
INPUT BEGIN
OLD /E1301-S1
CREF /200-B-4-B1 TAIL
CATR /AAZFBD0TT
OLD /E1301-S2
CREF /250-B-5-B1 HEAD
CATR /AAZFBD0TT
OLD /E1301-S3
CREF /250-B-5-B2 HEAD
CATR /AAZFBD0TT
OLD /E1301-T1
CREF /100-C-12-B2 TAIL
CATR /AAZFBB0NN
OLD /E1301-T2
CREF /100-C-13-B1 HEAD
CATR /AAZFBB0NN
1974 to current year.